NEW 10 TON AIR COOLED CHILLER (125,200 Btu/h) / 15 HP
$ 5280
- Description
- Size Guide
Description
10 Ton Air Cooled ChillerItem Features
Copeland
Scroll Compressor
with Advanced Scroll Temperature Protection
Danfoss
MCHE
(MicroChannel Heat Exchanger)
Schneider
Contactors and Relays
Omron
Phase Monitor
Propeller fan(s) induced air flow
Refrigerant sight glass with moisture indicator
Filter-drier
Danfoss
Thermostatic expansion valve
R410A
refrigerant
- Non-Ozone depleting
- Low global warming impact
Shell and Tube Type evaporator
Liquid line solenoid valve
Refrigerant high pressure gauges
Refrigerant low pressure gauges
Stainless Steel (
SUS304)
Water Tank
Multistage Centrifugal Pump
Standard Stainless Steel (SUS304) NPT fittings
Castors - for portability
Designed for indoor installation
Powder coated steel upright frame
Removable side panels for easy access
Cooling Capacity
kcal/h
31500
BTU/h
125,200
Nominal Tonnage
RT
10
Outlet Water Temp.
°F
50
Condension Temp.
°F
122
Power Supply
3PH-460V-60HZ
Max Amp
A
24
Total Power Input
HP
18
Power Supply Cable Diameter
mm²
AWG 11
Safety Protection Device
Overload, Inverse Phase, High/Low Pressure, Water Flow, Water Level &
Anti-Freeze Protection
Refrigerant
Type
R410A
Charge
Lbs
25
Compressor
Start Mode
Direct start
Type
Copeland Fully-Hermetic Scroll Type
Qty
1
HP
15
RLA (Running Load Amp)
16.7
LRA(Locked Rotor Amp)
125
Fan
Qty
2
Type
External Rotar Axial Fan
Power
HP
0.6×2
Current
A
1.0×2
LRA
A
6.0×2
Heat Rejection
BTU
/
Volume Air Flow
CFM
7000
Condenser
Type
Danfoss MCHE
Subcooling.
°F
9
Heat Rejection
BTU
162410
Evaporator
Type
Dry Shell and Tube Type
Subcooling.
°F
9
Heat Rejection
BTU
125,200
Cooled Water Flow
GPM
27.7
Water Pressure Drop
PSI
≤
12
Energy Adjust Mode
100%
Throttling Device
Mode
thermal expansion valve
Pipe
Water Outlet
MNPT 2"
Water Inlet
MNPT 2"
Water Pump
Flow
GPM
26.4
Head
PSI
49.3
Power
HP
1.5
LRA
A
13.2
Water Tank
Capacity
GAL
38
Sound Pressure
at 1 meter
DBA
72
Programming Controller
Display
Touch Screen Digital temperature display microcomputer controller
Output
-
Output Choice
Relay
Temp Control Range °F
+41 ~+95
Temp Control Accuracy °F
±3.6
1) Cooling tons based on 50
℉
leaving coolant and 95
℉
ambient air
2) Chilled water work allowed temperature range 41
℉
~
95
℉
.
3) Chilled water in and out temperature difference: 37.4
℉
~
46.4
℉
;
4) Allowed ambient temperature range: -4
℉
~
104
℉
5) Power supply: 3PH-460V-60Hz, Allowing the voltage fluctuate ±10%,
allow phase voltage difference ±2%, Allow the frequency range ±0.2Hz.